Intuitive: clearly structured measurement menu for volume flow and parallel determination of air velocity, humidity and temperature in ventilation ducts or at ventilation outlets
-
Clever: hot wire probe with telescope (0.85 m) – combine the vane probe (Ø 100 mm) with Bluetooth with the telescope for ceiling outlets or the funnel set for plate outlets (please order separately) as required
-
Convenient: wireless probe, internal data storage and USB port for data export
-
As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
-
Temperature - NTC Measuring range
-40 to +150 °C
Accuracy
±0.4 °C (-40 to -25.1 °C)
±0.3 °C (-25 to +74.9 °C)
±0.4 °C (+75 to +99.9 °C)
±0.5 % of mv (Remaining Range)
Resolution
0.1 °C
Temperature - TC Type K (NiCr-Ni) Measuring range
-200 to +1370 °C
Accuracy
±(0.3 °C + 0.3 % of mv)
Resolution
0.1 °C
General technical data Weight
250 g
Dimensions
154 x 65 x 32 mm
Operating temperature
-20 to +50 °C
Connectable probes
1 x digital probe with cable or 1 x Temperature NTC TUC, 1 x digital Bluetooth probe or testo Smart Probe, 1 x Temperature TC Type K
Product colour
black/orange
Battery type
3 AA mignon 1.5 V
Battery life
12 h (typically vane measurement)
Interface
Bluetooth®; USB
Storage temperature
-20 to +50 °C
-
General technical data Storage temperature
-20 to +60 °C
Weight
360 g
Dimensions
375 x 105 x 46 mm
Operating temperature
-5 to +50 °C
Probe head diameter
100 mm
Product colour
black/orange
Battery type
4 x type AA batteries
Battery life
60 h
Data transfer
Bluetooth®
Radio range
20 m
Temperature - NTC Measuring range
-20 to +70 °C
Accuracy
±0.5 °C
Resolution
0.1 °C
Velocity / Volume flow Measuring range
0.3 to 35 m/s
Accuracy
±(0.1 m/s + 1.5 % of mv) (0.3 to 20 m/s)
±(0.2 m/s + 1.5 % of mv) (20.01 to 35 m/s)
Resolution
0.01 m/s
-
Temperature - NTC Measuring range
-20 to +70 °C
Accuracy
±0.5 °C
Resolution
0.1 °C
Absolute Pressure Measuring range
+700 to +1100 hPa
Accuracy
±3.0 hPa
Resolution
0.1 hPa
Velocity - Hot wire Measuring range
0 to 30 m/s
Accuracy
±(0.03 m/s + 4 % of mv)
(0 to 20 m/s)
±(0.5 m/s + 5 % of mv)
(20.01 to 30 m/s)
Resolution
0.01 m/s
General technical data Storage temperature
-20 to +70 °C
Weight
90 g
Dimensions
315 x 12 x 12 mm
Operating temperature
-20 to +70 °C
Cable length
1.7 m
Length telescope
850 mm
Probe head diameter
9 mm
Diameter telescope
12 mm
Product colour
Black; silver
Diameter probe shaft
12 mm
-
General technical data Weight
1400 g
Dimensions
516 x 135 x 256 mm
Product colour
Black