testo 350 MARITIME - Exhaust gas analyzer for diesel ship engines

Order-Nr.  0563 3503

  • With DNV and NK certificate 

  • Unrestricted availability thanks to pre-calibrated gas sensors which are exchangeable on site

  • Ready to measure in less than 2 minutes

  • Tested gas sensors — as good as reference measurement technology

  • In addition, the flue gas analyzer complies with the guidelines for marine equipment according to Marine Equipment Directive (MED)

Testo proudly presents the world’s first portable exhaust gas analyzer for diesel ship engines: the testo 350 MARITIME! The groundbreaking exhaust gas analyzer measures emissions at diesel ship engines in compliance with MARPOL Annex VI and NOx Technical Code 2008.


Details

Product Description

The flue gas analyzer testo 350 MARITIME can be used for emission measurement on marine diesel engines for measuring the gaseous exhaust gas concentrations of NO, NO2, SO2, CO, CO2-(IR), O2. In order to meet the harsh requirements at sea, the complete flue gas analyzer, including accessories, is housed in a robust protective case with a trolley function – the testo 350 MARITIME flue gas analyzer certainly isn't a landlubber.

 

The testo 350 MARITIME flue gas analyzer goes full speed ahead

As a seaworthy flue gas analyzer, the testo 350 MARITIME can be used for the following on-board verification surveys in accordance with the NOx Technical Code 2008: For the simplified testing and measurement method, for instance if modifications have been made to the engine, such as readjustment
The testo 350 MARITIME flue gas analyzer is also suitable for checking the NOx limit values stipulated in MARPOL Annex VI. The NOx values are for example tested in official NOx checks. The NOx measurement can also be used to provide proof of NOx reduction, which is required in regional special zones with specific NOx tax requirements (such as Norway).

 

Outstanding: testo 350 MARITIME offers certified quality

The testo 350 MARITIME flue gas analyzer has the following certificates:
DNV Certificate No. TAA00001K0 Rev. 4, Nippon Kaiji Kyokai (Class NK) certificate no. TA23536M, MED Certificate No. MEDB0000328 Rev. 3 (Module B) and MEDD00002FU (Module D)

Delivery Scope

  • The testo 350 MARITIME V2 analyzer unit, equipped with NO, NO2, SO2, CO, CO2-(IR) and O2, including gas conditioning, measuring range extension for single slot (only for SO2), fresh air valve for long-term measurement, differential pressure sensor, temperature probe input type K NiCr-Ni and type S Pt10Rh-Pt, Testo data bus connection, rechargeable battery, integrated combustion air probe (NTC), trigger input, measurement data memory and USB interface
  • testo 350 MARITIME V2 Control Unit
  • Robust protective case with trolley function
  • Flue gas probe for industrial engines, 335 mm immersion depth including cone and heat protection plate, Tmax. +1,000°C, special hose for NO2-/SO2 measurements, length 4 m
  • Connection cable between flue gas analyzer and Control Unit, length 5 m
  • testo fast printer with wireless infrared interface, 1 roll of thermal paper and 4 mignon batteries for printing readings out on site
  • testo 610 humidity/temperature measuring instrument
  • DNV Certificate No. TAA00001K0 Rev. 4
  • Nippon Kaiji Kyokai (Class NK) certificate no. TA23536M
  • MED Certificate No. MEDB0000328 Rev. 3 (Module B) and MEDD00002FU (Module D)

Technical Data

General technical data

Weight

Approx. 17 kg

Dimensions

565 x 455 x 265 mm (case)

Operating temperature

5 to +45 °C

Product-/housing material

TPE/PC + ABS/PC + ABS + 10% GF

Connectable probes

1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x temperature probe; 1 x differential pressure

Product colour

Black

Standards

Germanischer Lloyd (DNV GL) Certificate Nippon Kaijik Kyokai (Class NK) certificate according to MARPOL Annex VI and NOx Technical Code 2008

Power supply

Li ion rechargeable battery; AC mains unit 100 V to 240 V (50 to 60 Hz)

Power consumption

max. 40 W

Pump flow

1 l / min. with flow monitoring

Max. pos. press./flue gas

50 mbar

Max. neg. press./flue gas

-300 mbar

Dewpoint calculation

0.04 °Ctd; 99 °Ctd

Interface

IR/IRDA interface; Bluetooth®; USB; data bus; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; Mains connection; dilution gas inlet for measurement range extension

Storage temperature

-20 to +50 °C

Temperature - TC Type K (NiCr-Ni)

Measuring range

-200 to +1370 °C

Accuracy

±0.4 °C (-100 to +200.0 °C)

±1.0 °C (-200 to -+1001.0 °C)

±1.0 °C (200 to +1370.0 °C)

Resolution

±0.1 °C (-200 to +1370.0 °C)

Absolute Pressure

Measuring range

600 to 1150 hPa

Accuracy

10.0

±10 hPa at -5 to 45 °C

Flue gas O₂

Measuring range

0 to 25 Vol.%

Accuracy

According to to MARPOL Annex VI and NOx Technical Code

Flue gas CO (with H₂-compensation)

Measuring range

0 to 3000 ppm

Accuracy

According to to MARPOL Annex VI and NOx Technical Code

Flue gas NO

Measuring range

0 to 3000 ppm

Accuracy

According to to MARPOL Annex VI and NOx Technical Code

Flue gas NO₂

Measuring range

0 to 500 ppm

Accuracy

According to to MARPOL Annex VI and NOx Technical Code

Flue gas SO₂

Measuring range

0 to 3000 ppm

Accuracy

According to to MARPOL Annex VI and NOx Technical Code

Flue gas CO₂ - NDIR

Measuring range

0 to 40 Vol.%

Accuracy

According to to MARPOL Annex VI and NOx Technical Code