ISO calibration certificate temperature
Order-Nr. 0520 0153
- Calibration points: -18 °C, 0 °C, +40 °C
-
ISO temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0001
- 3 calibration points: -18 / 0 / +60 °C
- For air/immersion probes
-
ISO calibration certificate for temperature - with selectable measuring points
Order-Nr. 0520 0141
- Calibration points freely selectable in the range -196 to +1200 °C (external probes), -40 to +180 °C (internal probes)
- For data loggers and transmitters
-
DAkkS temperature calibration certificate - with 5 measuring points
Order-Nr. 0520 0281
- 5 calibration points: -50 / 0 / +90 / +121 / +140 °C
- Internationally recognized according to DAkkS standard and binding in a court of law
-
ISO luminous intensity calibration certificate - with 5 measuring points
Order-Nr. 0520 0010
- 5 calibration points: 0 / 500 / 1,000 / 2,000 / 4,000 lx
- According to the ISO standard
-
ISO humidity calibration certificate - with 2 measuring points
Order-Nr. 0520 0006
- 2 calibration points: 11.3 and 75.3 %RH at +25°C
- According to the ISO standard
-
ISO flow calibration certificate - with 4 measuring points
Order-Nr. 0520 0004
- 4 calibration points: 1 / 2 / 5 / 10 m/s
- For hot wire anemometers, vane anemometers and Pitot tubes
-
ISO flow calibration certificate - with 4 measuring points
Order-Nr. 0520 0034
- 4 calibration points: 5 / 10 / 15 / 20 m/s
- For hot wire anemometers, vane anemometers and Pitot tubes
-
ISO temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0071
- According to the ISO standard
- 3 calibration points: +60 / +120 / +180 °C
-
ISO pressure calibration certificate - with 5 measuring points
Order-Nr. 0520 0025
- 5 calibration points distributed over the measuring range
- Accuracy 0.1 to 0.6 % of f.v.
-
ISO pressure calibration certificate - with 5 measuring points
Order-Nr. 0520 0005
- 5 calibration points distributed over the measuring range
- Accuracy > 0.6 % of f.v.
-
DAkkS temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0211
- 3 calibration points: -20 / 0 / +60 °C
- For air/immersion probes
-
DAkkS calibration certificate temperature - with 3 calibration points
Order-Nr. 0520 0262
- For data loggers and transmitters
- According to DAkkS standard: internationally recognized and binding in a court of law
-
ISO flow calibration certificate - with 4 measuring points
Order-Nr. 0520 0024
- 4 calibration points: 0.3 / 0.5 / 0.8 / 1.5 m/s
- For hot wire and vane anemometers
-
ISO calibration certificate/temperature - with 3 measuring points
Order-Nr. 0520 0401
- 3 calibration points: -18 / 0 /+ 60 °C
- For infrared measuring instruments/probes
-
DAkkS pressure calibration certificate - with 9 measuring points
Order-Nr. 0520 0215
- 9 calibration points distributed over the measuring range
- Accuracy 0.1 to 0.6 % of f.v.
-
DAkkS humidity calibration certificate - with 2 measuring points
Order-Nr. 0520 0206
- 2 calibration points: 11.3 and 75.3 %RH at +25 °C
- According to the DAkkS standard
-
ISO temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0021
- According to the ISO standard
- For air/immersion probes
-
ISO temperature calibration certificate - with 1 measuring point
Order-Nr. 0520 0072
- 1 calibration point: +60 °C
- For surface probes
-
ISO calibration certificate for flow - with 2 measuring points
Order-Nr. 0520 0094
- 2 calibration points: 5 / 10 m/s
- For anemometers and Pitot tubes
-
ISO temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0151
- 3 calibration points: -18 / 0 / +60 °C
- For data loggers and transmitters
-
ISO calibration certificate for temperature - with selectable measuring points
Order-Nr. 0520 0121
- Calibration points freely selectable in the range -15 to +480 °C
- For surface temperature probes
-
ISO calibration certificate for thermal imager - with three measuring points
Order-Nr. 0520 0490
- 3 calibration points: 0 / +100 / +200 °C
- Calibration of the thermal imager
-
ISO temperature calibration certificate - with 3 measuring points
Order-Nr. 0520 0181
- 3 calibration points: -8 / 0 / +40 °C
- For air/immersion probes
57 results found